false
true
39872d87:13e195515d3:-7aaa
3.1.2.20120830
true
580
outlinkHelp
false
false
Display
true
500
true
5
false
-1
-1
232
105
true
true
39872d87:13e195515d3:-7aa5
24
Grouping Container
true
true
false
true
false
Grouping Container
true
Default
155
0
false
1
31
40
false
true
0.0
39872d87:13e195515d3:-7aa4
24
true
Rectangle
false
255
true
true
false
true
Rectangle
true
false
Default
155
0
0
1
2
true
0
$(pv_name)
$(pv_value)
0
false
false
true
100.0
39872d87:13e195515d3:-7aa3
20
true
Rectangle
false
255
true
true
false
false
Rectangle
true
false
Default
151
0
0
1
0
true
2
$(pv_name)
$(pv_value)
2
false
true
true
39872d87:13e195515d3:-7a91
140
Grouping Container
true
true
false
true
false
Grouping Container
true
Default
507
0
false
1
415
-1
false
true
0.0
39872d87:13e195515d3:-7a8d
24
true
Rectangle
false
255
true
true
false
true
Rectangle
true
false
Default
154
0
0
1
2
true
10
$(pv_name)
$(pv_value)
41
false
false
true
100.0
39872d87:13e195515d3:-7a8c
20
true
Rectangle
false
255
true
true
false
false
Rectangle
true
false
Default
150
0
0
1
0
true
12
$(pv_name)
$(pv_value)
43
false
true
1
39872d87:13e195515d3:-7a90
false
14
Label
true
true
false
true
false
Label
true
this may or may not cause the target record to process. (The target
500
0
1
0
66
true
1
true
1
39872d87:13e195515d3:-7a8f
false
14
Label
true
true
false
true
false
Label
true
of the CA EPICS link command described above. This type of link
500
0
1
0
36
true
1
true
1
39872d87:13e195515d3:-7a8e
false
14
Label
true
true
false
true
false
Label
true
This
40
0
1
0
16
true
1
true
1
39872d87:13e195515d3:-7a8b
false
14
Label
true
true
false
true
false
Label
true
is a 'dynamic' link, an early prototype
300
0
1
0
16
true
201
false
true
20
true
100.0
39872d87:13e195515d3:-7a8a
0.0
0
1
true
Polyline
false
255
true
true
true
false
Polyline
true
false
Default
506
0
0
1
1
true
1
$(pv_name)
$(pv_value)
1
true
1
39872d87:13e195515d3:-7a89
false
14
Label
true
true
false
true
false
Label
true
xxx:scan1.EXSC
150
0
1
0
15
true
44
true
1
39872d87:13e195515d3:-7a88
false
14
Label
true
true
false
true
false
Label
true
record will decide.) If processing does occur, this link type
500
0
1
0
81
true
1
true
1
39872d87:13e195515d3:-7a87
false
14
Label
true
true
false
true
false
Label
true
normally will wait for it to complete. (Some displays will have a
500
0
1
0
96
true
1
true
1
39872d87:13e195515d3:-7a86
false
14
Label
true
true
false
true
false
Label
true
menu field nearby, which allows you to choose whether or not to wait.)
500
0
1
0
111
true
1
true
1
39872d87:13e195515d3:-7a85
false
14
Label
true
true
false
true
false
Label
true
500
0
1
0
126
true
1
true
1
39872d87:13e195515d3:-7a84
false
14
Label
true
true
false
true
false
Label
true
accepts only a PV name. It will write a value to the named PV, and
500
0
1
0
51
true
1
true
1
39872d87:13e195515d3:-7aa9
false
14
Label
true
true
false
true
false
Label
true
This
40
0
1
0
37
true
0
true
1
39872d87:13e195515d3:-7aa8
false
14
Label
true
true
false
true
false
Label
true
is a standard EPICS link.
300
0
1
0
37
true
200
true
1
39872d87:13e195515d3:-7aa7
false
14
Label
true
true
false
true
false
Label
true
It accepts a PV name, followed by a process command (e.g., ' NPP'),
500
0
1
0
60
true
0
true
1
39872d87:13e195515d3:-7aa6
false
14
Label
true
true
false
true
false
Label
true
followed by an alarm command (e.g., ' NMS'; ignore this.)
500
0
1
0
75
true
0
true
1
39872d87:13e195515d3:-7aa2
false
14
Label
true
true
false
true
false
Label
true
xxx:scan1.EXSC PP NMS
150
0
1
0
36
true
42
true
1
39872d87:13e195515d3:-7aa1
false
20
Label
true
true
false
true
false
Label
true
OUTPUT-LINK HELP
500
0
1
1
4
true
0
false
true
20
true
100.0
39872d87:13e195515d3:-7aa0
0.0
0
1
true
Polyline
false
255
true
true
true
false
Polyline
true
false
Default
506
0
0
1
1
true
25
$(pv_name)
$(pv_value)
0
true
1
39872d87:13e195515d3:-7a9f
false
14
Label
true
true
false
true
false
Label
true
Here are the possible process commands for an output link:
500
0
1
0
95
true
0
true
1
39872d87:13e195515d3:-7a9e
false
14
Label
true
true
false
true
false
Label
true
to process (as it would if you typed the value in by hand).
500
0
1
0
235
true
0
true
1
39872d87:13e195515d3:-7a9d
false
14
Label
true
true
false
true
false
Label
true
CA - Write a value. Let the target record decide whether or not
500
0
1
0
220
true
0
true
1
39872d87:13e195515d3:-7a9c
false
14
Label
true
true
false
true
false
Label
true
If you want EPICS to trace the processing (e.g., if the sscan
500
0
1
0
170
true
0
true
1
39872d87:13e195515d3:-7a9b
false
14
Label
true
true
false
true
false
Label
true
PP - Write a value and then process the target record.
500
0
1
0
155
true
0
true
1
39872d87:13e195515d3:-7a9a
false
14
Label
true
true
false
true
false
Label
true
record named in the link). This is the default command.
500
0
1
0
135
true
0
true
1
39872d87:13e195515d3:-7a99
false
14
Label
true
true
false
true
false
Label
true
NPP - Just write a value; don't process the target record (the
500
0
1
0
120
true
0
true
1
39872d87:13e195515d3:-7a98
false
14
Label
true
true
false
true
false
Label
true
record will drive this record, and wait for it to complete),
500
0
1
0
185
true
0
true
1
39872d87:13e195515d3:-7a97
false
14
Label
true
true
false
true
false
Label
true
then you must use 'PP'.
500
0
1
0
200
true
0
true
1
39872d87:13e195515d3:-7a96
false
14
Label
true
true
false
true
false
Label
true
If processing does occur, EPICS will not trace it.
500
0
1
0
250
true
0
true
1
39872d87:13e195515d3:-7a95
false
14
Label
true
true
false
true
false
Label
true
NOTE: If the target record is in a different crate, the process
500
0
1
0
275
true
0
true
1
39872d87:13e195515d3:-7a94
false
14
Label
true
true
false
true
false
Label
true
command is ignored; EPICS will behave as though 'CA' were specified,
500
0
1
0
290
true
0
true
1
39872d87:13e195515d3:-7a93
false
14
Label
true
true
false
true
false
Label
true
no matter what the link says. (If you want to wait for completion
500
0
1
0
305
true
0
true
1
39872d87:13e195515d3:-7a92
false
14
Label
true
true
false
true
false
Label
true
in this case, you must use a 'dynamic' link, described below.)
500
0
1
0
320
true
0
true
1
39872d87:13e195515d3:-7a83
false
14
Label
true
true
false
true
false
Label
true
NOTE: If the PV named in the link is itself a link field, you must
500
0
1
0
345
true
0
true
1
39872d87:13e195515d3:-7a82
false
14
Label
true
true
false
true
false
Label
true
specify the command 'CA'. (If you want to wait for completion in
500
0
1
0
360
true
0
true
1
39872d87:13e195515d3:-7a81
false
14
Label
true
true
false
true
false
Label
true
this case, you must use either the sseq or the sCalcout record,
500
0
1
0
375
true
0
true
1
39872d87:13e195515d3:-7a80
false
14
Label
true
true
false
true
false
Label
true
select 'CA', and set the link's WAIT field to 'Wait'.)
500
0
1
0
390
true
0